Discharge of Condition 6 of previously approved application LA06/2021/1220/F which states - Prior to the occupation of the proposed…
Lands to the rear of 23-61 Castle Street, Comber, BT23 5EA
Official description
Discharge of Condition 6 of previously approved application LA06/2021/1220/F which states - Prior to the occupation of the proposed development, a Verification Report shall be submitted to and agreed in writing by the Council. This report shall demonstrate that the remediation measures outlined in the Pentland Macdonald report; Contamination Assessment and remediation strategy, Castle Lane, Comber referenced PM19- 1137 and dated December 20219 have been implemented. The Verification Report shall demonstrate the successful completion of remediation works and that the site is now fit for end-use (Residential with Plant Uptake). It must demonstrate that the identified potential pollutant linkages are effectively broken. The Verification Report shall be in accordance with current guidance and best practice. In particular, this Verification Report must demonstrate that: • The final site layout including areas of hardstandlng, gardens and soft landscaped areas are as specified in the Site Plan Proposed Drawing No. 03A. • The emplacement of capping layers across gardens and landscaped areas is as specified: In garden areas- 1m capping layer comprising a capillary break layer of a minimum of 300mm of granular material; overlain by 700mm of clean subsoil and topsoil and in soft landscaped areas- the emplacement of a 0.5m thick capping layer of glean gravel/ subsoil topsoil. All material used in the capping layers must be demonstrably proven suitable for use. • Gas protection measures have been installed in line with a Characteristic Situation 2 scenario which attain a gas protection score of 3.5 (Table 4, B88485) and shall include two or more of the following measures: • Concrete floor slabs; • A proprietary gas resistant membrane installed across the entire footprint of the buildings; • A passively ventilated under floor void. The verification of the gas protection measures shall follow CIRIA C735 Good Practice on the testing and verification of protection systems for buildings against hazardous ground gases. Information Submitted: Verification Report
- Council
- Ards and North Down
- Reference
- LA06/2026/0523/DC
- Application type
- Discharge Of Condition
- Status
- Determined
- Decision
- Conditions
- Submitted
- 11 Jun 2026
- Decision date
- 21 Jul 2026
- Postcode
- BT23 5EA
More applications in Ards and North Down
Non-material changes to LA06/2023/1959/F: reducing gross floor area of the approved Culture Hub, at Ulster Folk and Transport Museum, with minor changes proposed to the window and…
Discharge of Condition 15 of previously approved application LA06/2025/0278/F which states - A programme of post-excavation analysis, preparation of an archaeological report…
Single storey rear extension
Single-storey rear extension
FIrst-floor extension to side.
2 no. illuminated shop signs on front and side elevation